Purpose

The purpose of this Post-Approval Study (PAS) is to evaluate the effectiveness of MPP to improve CRT response in the non-responder patient population when used in "real-world" clinical practice, following commercial release. This evaluation is based on the Clinical Composite Score which summarizes the proportions and frequencies of CRT non-responder patients who are "improved", "unchanged" or "worsened" after receiving MPP therapy. Patients will be followed for the duration of the PAS. This study is required by FDA as a condition of approval of the MPP feature and is integrated within the Product Surveillance Registry (PSR).

Condition

Eligibility

Eligible Ages
All ages
Eligible Genders
All
Accepts Healthy Volunteers
No

Inclusion Criteria

  • Patient or legally authorized representative provides written authorization and/or consent per institution and geographical requirements - Patient has or is intended to receive or be treated with an eligible CRT device - Patient within 30 days of therapy received at the time of their initial PSR platform enrollment

Exclusion Criteria

  • Patient who is, or is expected to be inaccessible for follow-up - Patient with exclusion criteria required by local law - Patient is currently enrolled in or plans to enroll in any concurrent drug and/or device study that may confound results

Study Design

Phase
Study Type
Observational [Patient Registry]
Observational Model
Cohort
Time Perspective
Prospective

Arm Groups

ArmDescriptionAssigned Intervention
CRT non-responders with MPP enabled Patients enrolled and implanted with a CRT Quad system, who are identified as CRT non-responder, for which MPP is enabled.
  • Device: Cardiac Resynchronization Therapy - MPP
    The multiple point pacing feature (MPP) is designed to allow pacing from 2 LV electrodes.

More Details

Status
Completed
Sponsor
Medtronic

Study Contact

Detailed Description

Medtronic market-released cardiac resynchronization therapy (CRT) Quadripolar (Quad) systems approved for commercial release with the Multiple Point Pacing (MPP) feature were eligible to contribute to the Post-Approval Study (PAS) objectives. Products with MPP capabilities receiving appropriate license or regulatory approval during the conduct of the PAS were included and contributed to the PAS objectives upon commercial release. CRT is an established pacing therapy for patients with heart failure (HF). CRT provides atrial- synchronized biventricular (BiV) pacing using standard pacing technology combined with a special third lead that is implanted via the coronary sinus and positioned in a cardiac vein to sense and/or pace the left ventricle (LV). Following a sensed atrial contraction or atrial paced event, both ventricles are stimulated to synchronize their contraction. The MPP feature is designed to allow a second LV pace to occur in LV Only or BiV pace configurations. In the LV Only pace configuration, the LV paces occur simultaneously or sequentially (LV- LV), as applicable by product. When Bi-V pacing is enabled, the RV pace can be delivered either before or after the LV paces, with the order determined by the programmed Ventricular Pacing Configuration. The MPP PAS was a global, prospective, observational multi-center study. Patients implanted with an eligible CRT Quad system were enrolled and followed in the Product Surveillance Registry per the expected standard of care practices of their care provider.

Notice

Study information shown on this site is derived from ClinicalTrials.gov (a public registry operated by the National Institutes of Health). The listing of studies provided is not certain to be all studies for which you might be eligible. Furthermore, study eligibility requirements can be difficult to understand and may change over time, so it is wise to speak with your medical care provider and individual research study teams when making decisions related to participation.